dc.descriptionEn los últimos años la utilización de técnicas de tratamientos radiante por modulación de intensidad (IMRT) ha ido creciendo hasta convertirse casi en un estándar en la Radioterapia moderna. La razón fundamental se basa en la posibilidad de obtener distribuciones de dosis más conformadas comparadas a técnicas conformadas 3D (CRT3D), aun en geometrías desfavorables, permitiendo una mayor protección de los tejidos sanos que circundan al tumor. El resultado de cada planificación produce como resultado un conjunto de complejos haces de intensidad modulada, que incluyen pequeños haces, irregulares y fuera de eje, donde es dificultoso predecir la dosis de cada uno. Estas características especiales de los haces obliga a que la fluencia de los mismos deban ser verificadas para garantizar que la dosis planificada a un paciente sea la que se desea entregar. En este trabajo se realizó una comparación del control de calidad de tratamientos de IMRT con MLC para distribuciones de dosis individuales y totales mediante film radiocrómicos, film radiográficos y arreglo bidimensional de cámaras de ionización en el Instituto de Radioterapia – Fundación Marie Curie, para tal fin se han implementado protocolos que abarcan la caracterización de los sistemas dosimétricos y evaluación de controles de calidad usando el criterio de análisis gamma [Y] para comparación de dosis medida y calculada registrando el número de píxeles con Y>1. Se analizaron 50 distribuciones de dosis del plan total con un criterio de análisis de 3% y un DTA 3mm (3%/3mm) y 50 campos individuales (5%/3mm) con los tres sistemas independiente y absoluta para cada plan empleando una cámara de ionización.-
dc.descriptionIn the last years the use of Intensity Modulation Radiation Therapy (IMRT) techniques had grow until becoming almost in a standard on the modern Radiotherapy. The reason of this success is the possibility to obtain better conformation of dose distribution compared to 3D Conformal Radiation Therapy (3DCRT), even with unfavorable geometries, allowing better normal tissue sparing. The result of each planning produced as a result a set of complex beams intensity modulated beams, including small beams, irregular and off-axis, where it is difficult to predict the dose. These special features of the beams require that the fluence the same should be verified to ensure that the planned dose to a patient is the one you want to deliver. In this work, a comparison of quality control with MLC IMRT treatments for individual dose distributions and total dose distributions using film radiochromic, film radiography and 2D cell array at the Instituto de Radioterapia – Fundación Marie Curie, for this purpose protocols have been implemented that cover dosimetry systems characterization and quality control evaluation using the criteria the gamma index [Y] to doses compared to measured and calculated recording the number of pixels with Y>1. 50 plans analyzed dose distributions of total plan with criteria ranging from 3% of dose difference or 3mm of distance to agreement (3%/3mm), and single distribution (3%/5mm) with the three independent systems y the absolute dosimetry for each composite plan is performed using an ionization chamber.-
dc.descriptionFil:Medina Pinzón, Luis Carlos. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.-
dc.formatapplication/pdf-
dc.languagespa-
dc.publisherFacultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires-
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.rightshttp://creativecommons.org/licenses/by/2.5/ar-
dc.source.urihttp://digital.bl.fcen.uba.ar/gsdl-282/cgi-bin/library.cgi?a=d&c=publicaciones/QED&d=004_QED_001-
dc.subjectQA IMRT-
dc.subjectFILM RADIOCHROMIC-
dc.subjectFILM RADIOGRAPHY AND 2D CELL ARRAY-
dc.subjectQA IMRT-
dc.subjectFILM RADIOGRAFICOS-
dc.subjectFILM RADIOCROMICOS-
dc.subjectARREGLO BIDIMENSIONAL DE CAMARAS DE IONIZACION-
dc.titleComparación de control de calidad de tratamientos de IMRT paciente específico mediante films radiocrómicos, films radiográficos y arreglo bidimensional de cámaras de ionización-